DDG-505Food & beverage processing

Added dust collection for a pizza production line

A 7,500 sq. ft. pizza production room scanned, its line modeled, and drawn as an existing-condition CAD package, so new dust collection hoods and ductwork can be routed against real heights and clearances.

Illustrative scope showing how the published tiers apply to a typical plant area. It is not a client project, and no client or site information is implied.

Scope data

Status
Example scope
Facility type
Food & beverage processing
Billable area
7,500 sq. ft.
Area type
Standard industrial
Tiers
Tiers 1–4 · Existing-Condition CAD Drawing Package
Process area
3,000 sq. ft.
Software
Autodesk Inventor, Autodesk Navisworks
Sheet
DDG-505

Interactive scope demo

Step through this scope

See this scope tier by tier, from the point cloud to the process model. All four tiers are in this scope. Proposed design appears dashed at Tier 3. Drag to orbit, or use the view buttons.

Click a tier to see the next deliverable

  • Building
  • Conveyors
  • Pizza line equipment
  • Capture hoods (proposed)
  • Ductwork (proposed)
  • Dust collector (proposed)
  • Rotary airlock, finger guard, flex sleeve & 55-gal drum (proposed)
  • Agreed process area

Tier 1 · Existing-Condition Scan

Registered point cloud of the production room and the existing pizza line: conveyors at their real heights, the sheeter, flour dusters, applicators, and oven, and the structure overhead. The dust collection system isn't built yet, so none of it is in the scan.

Tier 2 · Building Model

Floors, walls, columns, doors, and the ceiling of the production room modeled. The line stays in the point cloud.

Tier 3 · Building & Process Model

Conveyors, sheeter, flour dusters, and sauce and topping applicators modeled from the scan within the agreed process area (gold outline); the oven beyond it stays in the point cloud. Dashed: the proposed dust collection design, with capture hoods at the dusting points, ductwork with blast gates, the indoor dust collector, and, called out, the rotary airlock with finger guard and flex sleeve discharging into a 55-gallon drum.

Proposed items (dashed) are design, not scan data.

Tier 4 · Existing-Condition CAD Drawing Package: not shown in this demo.Sample sheets (PDF)

Gold tripods mark simulated Leica RTC360 setups. Simulated geometry, not a client facility.

Fig. 1 Pizza line with an added dust collection system (proposed) · Tiers 1–4 in scopeSimulated geometry, not a client facility

Tiers 1–4 in this scope

  1. Tier 1: Existing-Condition Scan

    Included

  2. Tier 2: Building Model

    Included

  3. Tier 3: Building & Process Model

    Included

  4. Tier 4: Existing-Condition CAD Drawing Package

    Included

Tiers are cumulative: each includes the ones before it. What each tier includes

Typical situation

A pizza plant is adding dust collection to an existing production line. Flour dusters along the line put excess flour into the air. The plan is to pick it up with capture hoods at the dusting points and carry it through new ductwork to an indoor dust collector, which discharges through a rotary airlock with a finger guard and a flex sleeve into a 55-gallon drum.

The ductwork has to fit around a line that’s already running: the conveyors, sheeter, sauce and topping applicators, and oven, plus the utilities and structure overhead. The layout needs real conveyor heights, hood locations, overhead utilities, and clearances, which old drawings rarely show.

What this scope includes

  • Tier 1, scan. 7,500 sq. ft. at the standard-industrial rate: the production room with the line, the space where the collector will stand, and the overhead zone the duct routes cross. Setups run along both sides of the line, so conveyors and equipment are captured from more than one side and overhead utilities are captured from below.
  • Tier 2, building. Floors, walls, ceilings, roof geometry where safely captured, stairs, doors, and building-access ladders for the full area, so the duct routes have their column lines and overhead clearances.
  • Tier 3, process. Limited to the agreed 3,000 sq. ft. around the dusting points and the collector location: external geometry and major visible connections of the conveyors, sheeter, flour dusters, and sauce and topping applicators. The oven and cooling conveyor, outside the process area, aren’t modeled, and neither are utilities outside the agreed systems, such as lights and cable trays; they stay visible in the point cloud for clash checks.
  • Tier 4, drawings. A plan of the production room, an equipment layout of the line, elevations along the duct route, sections at the dusting points and the collector location, equipment tags, and agreed layout dimensions, with one consolidated review round. Delivered as a PDF set plus editable DWG. These record existing conditions; the new hoods and ductwork are drawn as part of the separate design work below.

Designing the dust collection

The scan and model document what’s there today. The dust collection design itself, from hood locations and duct routing with blast gates to the collector and the rotary airlock, finger guard, flex sleeve, and drum at its discharge, is separate design work at the published hourly rates. The demo above shows it as proposed design, not scan data.

New hoods and duct routes are laid out against the model, then checked against the model and point cloud in Navisworks, so clashes with the line, utilities, and structure show up before anything is fabricated or installed.

Flour dust is combustible, so the final design follows the plant’s dust hazard analysis. The scan and model record existing conditions; they don’t establish code compliance.

What’s excluded

  • The dust hazard analysis, airflow and duct-sizing calculations, and permit documents
  • Fabrication drawings of the hoods and ductwork, which are separate scopes
  • Equipment internals, including the inside of the oven and dusters, and detailed supports

Fabrication-critical tie-ins, flange locations, anchor bolts, and tight-clearance dimensions need separate verification before fabrication or installation, quoted separately. Verification rule

Budgetary · September 21, 2026 rates

Budgetary low end at current rates

$13,500

At the low end of every published range · final price by written proposal

Budgetary breakdown by tier at the current published rates
ItemBudget
Tier 1 — Standard industrial scanning7,500 sq. ft. × $0.20/sq. ft.Minimum applies$2,500
Tier 2 — Building modeling add-on7,500 sq. ft. × $0.30–$0.60/sq. ft.Minimum applies$3,000
Tier 3 — Process-modeling add-on3,000 sq. ft. × $0.60–$1.50/sq. ft.Minimum applies$5,000
Tier 4 — CAD drawing package7,500 sq. ft. × $0.40–$0.80/sq. ft.$3,000
Budgetary total, low end$13,500
  • High-congestion process areas are quoted separately.
  • Where the drawing rate falls in the range depends on equipment density and the agreed sheet list.
  • Includes one scheduled mobilization within 50 driving miles of headquarters.

Computed from the published rates using this example’s area, area type, process area, and tiers, taking the low end of each range. Heavier congestion, restricted access, or a longer sheet list moves a line up within its published range.

How this area is captured

Area type: Standard industrial

Setups are placed around equipment and along piping runs so connections are captured from more than one side, at ranges that keep the areas that matter close to the scanner.

Leica RTC3601.9 mm @ 10 mHow accuracy works

† Leica manufacturer specification (68% confidence, 89% albedo). An instrument figure, not a project tolerance.

Have a plant area like this one?

Send the facility type, approximate area, and what you need delivered. You’ll get a budgetary number and a written proposal with a fixed scope.